hayward blue essence troubleshootinganna kate hutter wanaka new zealand

If outlet is melted, youll need a replacement. New Assy is $500. Second most common air leak on a Super Pump would be the incoming pipe fitting. Improper voltage wiring is the usual culprit for smoking pump motors. Replacement for Hayward T-Cell-15. 1. To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. I turned off my pool at the control box for 24 hours as I needed a union replaced at the salt cell. IF the motor is turning over or starting, but no water pumps, it is usually an air leak from a loose pipe coming into the pump, or a loose pump lid. JavaScript is disabled. Loose wire connections or touching terminal connections cause sparking. Too much air usually just gets pushed through the filter and back to the pool, or the pump will lose prime if there really is too much air. Thank you very much in advance. The capacitor is the black cylinder on the left side, you can replace the capacitor at a low cost. I have a Hayward SP2610X15 Super Pump 1.5-HP Max-Rated Single-Speed Pool Pump, Hi, my Hayward super pump is thermo protected. . was spinning counter clockwise. Is that a result of all the water that got in the equipment during the storm? Don, melted shrouds can indicate that the something may be laying on the burner tray, causing flames to shoot out a little sideways, or something is laying on (or clogging) the heat exchanger, allowing hot gas to build up inside the heater, slowing down the exhaust rate. so.it shut off again. Terrible storms 2 nights ago. Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. https://www.facebook.com/inyopoolsFOLLOW us on TWITTER! La mayora de las veces la vlvula de gas est cerrada, el tanque de propano est bajo, el encendedor est roto o el sensor de fuego no est colocado correctamente. Water level is good, changed basket lid seal, all unions are tight. My pump motor runs for 3-5 minutes ant then shuts off for about the same time. 2. When it cools it automatically trys to start again and motor turns on after 3 seconds of humming. training events, warranty Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). I was hoping that you can give me some advice. Hi Jim, bummer! If the wrong o-ring size was used, that could cause the problem. Even though the motor is only 2 months old and had very little run time, bench running it sounds pretty horrible. Step 1: Wait 60 seconds after the pump starts. The mechanical shaft seal sits behind the impeller, and prevent water from leaking out along the motor shaft. "width": "611",
Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. 5. inspect all wires inside the back of motor, looking for one that is disconnected, cut, crimped, or two metal terminals touching each other. but the digital display panel wont light up, does the propane need to be connected and turned on to make the display panel work?? External bypass is out of adjustment. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. 5. Jul 8, 2018 #1 I have a blue essense 20,000 salt system and can find very little online. Likewise, it could be any other obstruction after the pump (partially clogged pipes, small pipe size, partially closed return valves) all of which will produce higher than normal filter pressure. thank you. This spray is not usually noticed, unless the pump has been running nearly full-head or full-speed. Get support by contacting us online, hayward Loose connection inside the plug or socket. Thats not right if it is a 3-phase motor, perhaps the wires are switched, but for a regular hayward pump (residential) 3-phase power would be very rare. If it is on low it works properly. Nothing seems to give it juice. It was only 3 years old. Hi Renaud, many motors come wired to accept 230V, but are reversible to 115V. Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. Power going in, but power not coming out and therein lies the problem, which could just be a loose wire, broken wire or faulty resistor/capacitor/relay. Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. There are ants around the AutoChlor, the lights come on but which is the problem, the pump or the switching system? First, I want to ensure the pool is voltage free, thus grounded and all components are bonded, I know many pumps have a zinc plate that actually bonds the water. Grass clippings, seeds, gravel or other small debris can clog an impeller and reduce suction. The most common areas for an air leak are the pump lid (is it as tight as possible? Whats that part called in case I do break it? You could remove the filter grid completely from the tank (and clean well), start the pump without the grid assembly inside (removing most of the resistance) and see how the water flows. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. All Rights Reserved. If youre reading this blog that means you need help troubleshooting your Hayward Aqua Rite salt system. switch and to the capacitor, to be sure nothing is loose or no crimped wires. Hayward pumps come in a variety of horsepowers, voltages and speeds. Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. Could this be true? The salt level is 2300 ppm or less and no chlorine is generating. Hi Kathleen, sounds like a leak from the shaft seal, unless water is running out of the pump exit fitting, and running down the housing and dripping off the bottom. If you find out, I would check the owners manual for information related to your symptoms. could be cord problem, too. it will not pull up off the pump basket. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The new pump was very quiet yesterday when I installed it, but this morning, I notice there is a slight medium pitch hum in the system. Backwash your filter when pressure gauge rises 7-9 psi above the clean, starting pressure. I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. My 4 year old pump is working well so I am not looking to switch it, but I am curious if I should consider raising its location to above pool water level. Our variable speed Hayward pump, when not running on highest speed, keeps resulting in FLO errors. Use a Drain King to pressurize the pipe backwards, to remove such clogs. After troubleshooting using your TS guide, I found on page 36 where it says to check the top rectifier I have 24VAC from the board (where the orange wire plugs into) to the ground. Sometimes this can be cleared or removed, without pulling the pump apart, which is def. 58 amps! Hi, is there a GFI on the outlet? Perhaps it could be flow related, if the pump is cavitating or starved for water like if you only have 3/4 or 1 pipes (?). Hi Theresa, if the pump is overheating, and shutting off for 20 minutes to cool down and then starting again, thats not usually a good sign, altho could be incorrect voltage or loose connections. Lube should not be the issue with the leak, not required. any ideas? Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. Ob, and its just over 4 yrs old. I will be replacing it tomorrow along with the electric socket. Corrosion inside the plug or socket. Not that I can think of, but something seems to be aerating your water? 12 ga or 14 ga? Yours may have become weak, or damaged somehow. Now when my sweeper comes on my waterfall feature from my spa does not turn off like it should and my sweeper moves slowly and in circles. Hello. Fourth, bad capacitor on the motor? The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. I think I have some air leakage on my supply side of my Hayward Super Pump. Turned everything off, let the motor cool off and tried again. Once it finishes calibrating, cycle the main switch from AUTO to SUPER CHLORINATE and back to AUTO. If none of those things, perhaps the filter grid needs to be soaked in a Filter Cleaner, to remove oils or minerals that have clogged the pores of the fabric. Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. Otherwise, it can be loose or corroded connections on the 3 wires that connect the motor to the drive. If it an older installation, I would again check the water chemistry to make sure it is balanced correctly. Gas pressure is ok. Any ideas? Hi Freddy, usually a clicking noise may be a relay, which are used in control systems for pools. Do they sometimes have to be replaced? But your superpump is fine on your AG pool. So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? Hi, loud screeching sounds like bearings, yes. Hi Thomas, the fitting that goes into the pump, was it also replaced? When I turn the pump on, the Thicker hose Between the pump and sand filter pops out of the end that is connected to the filter. Hi Pat, yes they should be plug and play, was the cord attached already, or did you install? "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. Be sure the wiring is tight on both ends. Select Product to Register: Step 4: Enter the registration information for your product . Perflex filters can clog up with heavy oils, or not enough DE powder, or if undersized for the pool (just like any other filter), so it could be the filter yes. Also installed a brand new circuit box to allow for the bigger pump its a 20A GFCI breaker with 12 gauge wire going to the pump. Am I doing something simply stupid, or should I call the pool people tomorrow? It would be best to not abandon the pipe if possible, best for water quality, clarity and turnover rates but sometimes thats not feasible so either way will work! it runs There is also a leak somewhere in the system because there is water on the pad. Now if it really is your pump, and not the heater making this noise, that I cant explain, must be the heater? With the pump off, remove the basket and reach your hand back into the eye of the impeller. You are using an out of date browser. Hi Carl, check for an air leak in front of the pump on the suction manifold, or around the pump lid, or on around the threads of the fitting that screws into the pump. So we have power to the pump. Weve not had this issue the past 2 years (we bought the house 2 years ago). American Freight San Antonio, . If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). It was working fine (all 3 speeds) until yesterday. If the pump is not grounded correctly, might that have something to do with it tripping? 1.5 horse power. low speed works fine, pump is three years old. The water level is good. He said its drawing 58 amps. Have a Hayward pump. I then tried the pump at various speeds and it did not prime and circulate the water through the pool. Im having a problem with my super pump. Could be from a large buildup of rust inside, between the stator and motor, but that usually frees up after running for just a minute. There is another switch located at 6 oclock called the stationary switch. After that, putting it to filter (following the backwash) ramps the flow to full strength until the gradual decline cycle starts again. "@type": "ImageObject",
I was going to try one of those next, as it seems impossible to keep water in the line without it draining into the pool. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. But now Im trying to plug it in and it doesnt make any noise at all. If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. I figure bearing, I pulled the motor off the housing and cleaned a few pine needles out of impeller but nothing else.Its only 2 years old,I take really good care of the equipment so Im surprised. Hi, I have a Hayward pump and it was running my barracuda g3 just fine but it stopped hours later. Hayward, Create a Pool Owner You may be removing the wrong bolts, if you are trying to loosen the 4 bolts that attach the motor to the seal plate. The issue continue to happen so I called a pool repair technician and he came out and verified that the filter was put together properly and also replaced the O-rings in the backwash valve. Any ideas on what may be going on? Could be a change in vibration, press down on the pump, to see if the tone changes. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted It doesnt mean it is ready to go at 230. Blue Essence Replacement Salt Chlorinators and Salt Cells Rust can develop inside the motor that you can break free, by spinning the shaft a few times. Thank you. Hayward Pool Products, We are here to help with all of your Now if you do find power at the motor, and the wires are screwed tightly, but no sound, no movement, and the breaker doesnt trip it could be a bad motor. If valve is open when it should be closed the heater will shut down and go into lockout. Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. Knowing prime was lost I filled the pool and the filter housing up with water. From the salt water panel into electrical panel/ timer there are three cables (ground, common and hot). Troubleshooting and diagnosing their problems. 4. leaky valve or unions in front of pump Does it only do this when vacuuming, but otherwise runs fine? ), maybe you can swap Assy B motor, but you say thats noisey, it could need new bearings and shaft seal. Occasionally, while running, it trips the breaker. Your pressure should be much lower, maybe 5-10 psi, without the cartridge in place. Hayward Aquarite T-CELL-5 | 20,000G Replacement Cell - Salt Pool Store Could the filter be plumbed backwards possibly? 1. 4. remove rear motor cover, loosen screw that holds capacitor (9 oclock) and move it out of the way, so you can fit a 7/16 wrench on the rear of the motor shaft, behind the centrifugal switch. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. "logo": {
Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. Hi Bill, when it goes into spa mode, the spa drain valve should open, and close off the pool suction valves, so that all the water is coming into the pump from the spa only. Hi, it does sound like a bad seal yes. Any tips? I have a brand new Hayward super pump for my inground pool that my husband bought last year..this morning i turned it on and when i checked it about an hour later i noticed it was off and water around the switch and the plug and i also noticed there must have been a leak in the hose where the water can be drained from the pool so im guessi g the hose sprung a leak and wet everything..i checked the timer and the breaker and switched them off and on again and still no power..i saw a switch on the back of the pump and flipped it off then on again and still no power..im guessing it couldve got fried but im hoping im wrong..please help. All breakers are good. The ampage to the pump has been the same since we got the pump 7 years ago and never had this issue before. The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. When they fail, they often crack, bulge, leak or smell bad, but not always. Water level is good, pipe connections are sealed and I checked I rings which seem fineI cant seem to figure out what is wrong. We replaced fhe shaft seal but the pump doesnt pull any water in there is no suction. No lights are coming on as if no power. No moisture. As I started to prep for this season, I did notice that the positive and negative electrical terminals on the 3 prong cord were corroded and loose. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. To reset your average salt level, turn the unit to OFF and then back to AUTO. Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. Slide your main switch to the AUTO position. Thanks a lot! If you are running the pump at full steam, and then shut it off, while looking very closely at these areas, you may see a quick spurt of water, which is where the air leak is originating from. 1.5 hayward pool pump motor clicks on and off rapidy. more, View Hi Virgil, the time clock may not be set, or if you have a controller, the on/off program may not be setup, so it runs until it is set to turn off but is not set to turn back on again? Ours is doing the same thing. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. The article says: Check for possible disruption inside of the flow T. Installation requires 12 inches of straight pipe before the flow switch. The issue is not a pump problem, not a filter problem, but a multiport valve problem. You can consult the flow charts for each model, to compare flow rates among two pumps, with a given (or assumed) level of resistance (feet of head). Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. Minglin. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. We have parts for the Super pump. Inspect the pipe/union connections on the suction side for loose connections or damaged pipes. "publisher": {
Home / Pool Equipment / Pool Heaters & Heat Pumps / Hayward Pool Heater Troubleshooting Hayward Pool Heater Troubleshooting September 24, 2019 March 3, 2023 Mark Garcia Check the wiring in the back of the motor, is the cord firmly attached? Pull the motor out of the pump and turn it on briefly, to see if the noise remains. Turned it off tho clear the skimmer basket.. water level is correct. Power Pole Distribution Block, I bought a new pump thinking was something wrong with pump on off switch. I checked the 20A fuse and it is good. This error can result commonly in springtime, after the pump has sat all winter rust can develop between the stator and rotor. When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. 3. It trips 20amp breaker after running 5 or 10 second. I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. Hi Rose, Its common that winterized pumps may freeze up, caused by a rust layer inside the motor. What do I need to do to fix this? Any idea what the next most likely culprit could be? Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Also be sure the vent holes for the motor are not blocked. I think I have a different problem with the pump now. The pipe connection became disconnected and flooded the pool house overnight after initial opening and start up pull the water through. Profile, Create a Pool Professional voltage reachs the stationary switch. Last year it worked great. We cant figure put how to get the pump going they have a circuit box outside its hooked to but it seems its not working. It is usually set to run at high rpm early morning and that is before sun hits it. Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. Thats good such frozen motors are common in the spring. We opened the pool a few weeks back with no pump motor problems. Do you have any idea what I need to do to remedy the problem. Turned on the motor and smoke and a oil type substance came out of the capacitor. Water Features, View All More commonly, you may experience sparks, or a small popping sound as you drain the capacitor, if there is a lot of power stored. You might also check the the motor is not bound up, reaching in behind the basket to be sure you can spin the impeller with your fingertips. You will need a new plug and a new outlet and maybe a new pump too (? You could use a small plug-in pump timer that would allow you to not unplug, just flip the switch to off. Samsung Da29-00020b 3 Pack, The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. how to watch past broadcasts on twitch. if it does not come back on, check switches, turn breaker all the way off and back on again. What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). How can I secure the top to the filter so the water will not pour out of it while the pump is on filter mode? Fox Nation Customer Service Phone, Most Famous Far Side Cartoons, Why Do Sovereign Citizens Say They Are Traveling, Message From A Loved One In Heaven App, When To Separate Pregnant Guppy, Articles H
Follow me!">

Hi Tony, there could be a short in the motor, or loose wires connecting to the capacitor, or if the capacitor you are replacing with is not the correct capacitor, or if the centrifugal or stationary switches are not releasing the capacitor, due to loose or misaligned switches, or loose wires, or wires shorting out by touching other wires or the motor casing, or crimped wires give a good look around the back of the motor, and try another capacitor, maybe call Hayward and ask for the correct capacitor MFD number for your horsepower of Northstar. Next time it happens, check power on the timeclock, or inspect the motor, looking thru the visual motor check window (again, only on Intermatic clocks), if no power is getting to the clock, replace the breaker, and/or wiring. Recently I started getting a loud vibration hum from my hayward pump. Or is it coincidence that I have a bad line in the pool. Flush out the housing to clear debris, then refill with water. What am I doing wrong?? I just bought this pump 3-4 yrs ago? Nothing is making any noise now and pump is not working at all. View Details Usfitnessfinder.com. I have a max-flo XL pump how high should it read it keeps going over 20 psi is this normal. You can use a pool putty to seal up some incoming leaks, but sometimes new parts are needed. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
If outlet is melted, youll need a replacement. New Assy is $500. Second most common air leak on a Super Pump would be the incoming pipe fitting. Improper voltage wiring is the usual culprit for smoking pump motors. Replacement for Hayward T-Cell-15. 1. To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. I turned off my pool at the control box for 24 hours as I needed a union replaced at the salt cell. IF the motor is turning over or starting, but no water pumps, it is usually an air leak from a loose pipe coming into the pump, or a loose pump lid. JavaScript is disabled. Loose wire connections or touching terminal connections cause sparking. Too much air usually just gets pushed through the filter and back to the pool, or the pump will lose prime if there really is too much air. Thank you very much in advance. The capacitor is the black cylinder on the left side, you can replace the capacitor at a low cost. I have a Hayward SP2610X15 Super Pump 1.5-HP Max-Rated Single-Speed Pool Pump, Hi, my Hayward super pump is thermo protected. . was spinning counter clockwise. Is that a result of all the water that got in the equipment during the storm? Don, melted shrouds can indicate that the something may be laying on the burner tray, causing flames to shoot out a little sideways, or something is laying on (or clogging) the heat exchanger, allowing hot gas to build up inside the heater, slowing down the exhaust rate. so.it shut off again. Terrible storms 2 nights ago. Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. https://www.facebook.com/inyopoolsFOLLOW us on TWITTER! La mayora de las veces la vlvula de gas est cerrada, el tanque de propano est bajo, el encendedor est roto o el sensor de fuego no est colocado correctamente. Water level is good, changed basket lid seal, all unions are tight. My pump motor runs for 3-5 minutes ant then shuts off for about the same time. 2. When it cools it automatically trys to start again and motor turns on after 3 seconds of humming. training events, warranty Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). I was hoping that you can give me some advice. Hi Jim, bummer! If the wrong o-ring size was used, that could cause the problem. Even though the motor is only 2 months old and had very little run time, bench running it sounds pretty horrible. Step 1: Wait 60 seconds after the pump starts. The mechanical shaft seal sits behind the impeller, and prevent water from leaking out along the motor shaft. "width": "611",
Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. 5. inspect all wires inside the back of motor, looking for one that is disconnected, cut, crimped, or two metal terminals touching each other. but the digital display panel wont light up, does the propane need to be connected and turned on to make the display panel work?? External bypass is out of adjustment. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. 5. Jul 8, 2018 #1 I have a blue essense 20,000 salt system and can find very little online. Likewise, it could be any other obstruction after the pump (partially clogged pipes, small pipe size, partially closed return valves) all of which will produce higher than normal filter pressure. thank you. This spray is not usually noticed, unless the pump has been running nearly full-head or full-speed. Get support by contacting us online, hayward Loose connection inside the plug or socket. Thats not right if it is a 3-phase motor, perhaps the wires are switched, but for a regular hayward pump (residential) 3-phase power would be very rare. If it is on low it works properly. Nothing seems to give it juice. It was only 3 years old. Hi Renaud, many motors come wired to accept 230V, but are reversible to 115V. Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. Power going in, but power not coming out and therein lies the problem, which could just be a loose wire, broken wire or faulty resistor/capacitor/relay. Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. There are ants around the AutoChlor, the lights come on but which is the problem, the pump or the switching system? First, I want to ensure the pool is voltage free, thus grounded and all components are bonded, I know many pumps have a zinc plate that actually bonds the water. Grass clippings, seeds, gravel or other small debris can clog an impeller and reduce suction. The most common areas for an air leak are the pump lid (is it as tight as possible? Whats that part called in case I do break it? You could remove the filter grid completely from the tank (and clean well), start the pump without the grid assembly inside (removing most of the resistance) and see how the water flows. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. All Rights Reserved. If youre reading this blog that means you need help troubleshooting your Hayward Aqua Rite salt system. switch and to the capacitor, to be sure nothing is loose or no crimped wires. Hayward pumps come in a variety of horsepowers, voltages and speeds. Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. Could this be true? The salt level is 2300 ppm or less and no chlorine is generating. Hi Kathleen, sounds like a leak from the shaft seal, unless water is running out of the pump exit fitting, and running down the housing and dripping off the bottom. If you find out, I would check the owners manual for information related to your symptoms. could be cord problem, too. it will not pull up off the pump basket. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The new pump was very quiet yesterday when I installed it, but this morning, I notice there is a slight medium pitch hum in the system. Backwash your filter when pressure gauge rises 7-9 psi above the clean, starting pressure. I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. My 4 year old pump is working well so I am not looking to switch it, but I am curious if I should consider raising its location to above pool water level. Our variable speed Hayward pump, when not running on highest speed, keeps resulting in FLO errors. Use a Drain King to pressurize the pipe backwards, to remove such clogs. After troubleshooting using your TS guide, I found on page 36 where it says to check the top rectifier I have 24VAC from the board (where the orange wire plugs into) to the ground. Sometimes this can be cleared or removed, without pulling the pump apart, which is def. 58 amps! Hi, is there a GFI on the outlet? Perhaps it could be flow related, if the pump is cavitating or starved for water like if you only have 3/4 or 1 pipes (?). Hi Theresa, if the pump is overheating, and shutting off for 20 minutes to cool down and then starting again, thats not usually a good sign, altho could be incorrect voltage or loose connections. Lube should not be the issue with the leak, not required. any ideas? Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. Ob, and its just over 4 yrs old. I will be replacing it tomorrow along with the electric socket. Corrosion inside the plug or socket. Not that I can think of, but something seems to be aerating your water? 12 ga or 14 ga? Yours may have become weak, or damaged somehow. Now when my sweeper comes on my waterfall feature from my spa does not turn off like it should and my sweeper moves slowly and in circles. Hello. Fourth, bad capacitor on the motor? The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. I think I have some air leakage on my supply side of my Hayward Super Pump. Turned everything off, let the motor cool off and tried again. Once it finishes calibrating, cycle the main switch from AUTO to SUPER CHLORINATE and back to AUTO. If none of those things, perhaps the filter grid needs to be soaked in a Filter Cleaner, to remove oils or minerals that have clogged the pores of the fabric. Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. Otherwise, it can be loose or corroded connections on the 3 wires that connect the motor to the drive. If it an older installation, I would again check the water chemistry to make sure it is balanced correctly. Gas pressure is ok. Any ideas? Hi Freddy, usually a clicking noise may be a relay, which are used in control systems for pools. Do they sometimes have to be replaced? But your superpump is fine on your AG pool. So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? Hi, loud screeching sounds like bearings, yes. Hi Thomas, the fitting that goes into the pump, was it also replaced? When I turn the pump on, the Thicker hose Between the pump and sand filter pops out of the end that is connected to the filter. Hi Pat, yes they should be plug and play, was the cord attached already, or did you install? "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. Be sure the wiring is tight on both ends. Select Product to Register: Step 4: Enter the registration information for your product . Perflex filters can clog up with heavy oils, or not enough DE powder, or if undersized for the pool (just like any other filter), so it could be the filter yes. Also installed a brand new circuit box to allow for the bigger pump its a 20A GFCI breaker with 12 gauge wire going to the pump. Am I doing something simply stupid, or should I call the pool people tomorrow? It would be best to not abandon the pipe if possible, best for water quality, clarity and turnover rates but sometimes thats not feasible so either way will work! it runs There is also a leak somewhere in the system because there is water on the pad. Now if it really is your pump, and not the heater making this noise, that I cant explain, must be the heater? With the pump off, remove the basket and reach your hand back into the eye of the impeller. You are using an out of date browser. Hi Carl, check for an air leak in front of the pump on the suction manifold, or around the pump lid, or on around the threads of the fitting that screws into the pump. So we have power to the pump. Weve not had this issue the past 2 years (we bought the house 2 years ago). American Freight San Antonio, . If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). It was working fine (all 3 speeds) until yesterday. If the pump is not grounded correctly, might that have something to do with it tripping? 1.5 horse power. low speed works fine, pump is three years old. The water level is good. He said its drawing 58 amps. Have a Hayward pump. I then tried the pump at various speeds and it did not prime and circulate the water through the pool. Im having a problem with my super pump. Could be from a large buildup of rust inside, between the stator and motor, but that usually frees up after running for just a minute. There is another switch located at 6 oclock called the stationary switch. After that, putting it to filter (following the backwash) ramps the flow to full strength until the gradual decline cycle starts again. "@type": "ImageObject",
I was going to try one of those next, as it seems impossible to keep water in the line without it draining into the pool. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. But now Im trying to plug it in and it doesnt make any noise at all. If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. I figure bearing, I pulled the motor off the housing and cleaned a few pine needles out of impeller but nothing else.Its only 2 years old,I take really good care of the equipment so Im surprised. Hi, I have a Hayward pump and it was running my barracuda g3 just fine but it stopped hours later. Hayward, Create a Pool Owner You may be removing the wrong bolts, if you are trying to loosen the 4 bolts that attach the motor to the seal plate. The issue continue to happen so I called a pool repair technician and he came out and verified that the filter was put together properly and also replaced the O-rings in the backwash valve. Any ideas on what may be going on? Could be a change in vibration, press down on the pump, to see if the tone changes. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted It doesnt mean it is ready to go at 230. Blue Essence Replacement Salt Chlorinators and Salt Cells Rust can develop inside the motor that you can break free, by spinning the shaft a few times. Thank you. Hayward Pool Products, We are here to help with all of your Now if you do find power at the motor, and the wires are screwed tightly, but no sound, no movement, and the breaker doesnt trip it could be a bad motor. If valve is open when it should be closed the heater will shut down and go into lockout. Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. Knowing prime was lost I filled the pool and the filter housing up with water. From the salt water panel into electrical panel/ timer there are three cables (ground, common and hot). Troubleshooting and diagnosing their problems. 4. leaky valve or unions in front of pump Does it only do this when vacuuming, but otherwise runs fine? ), maybe you can swap Assy B motor, but you say thats noisey, it could need new bearings and shaft seal. Occasionally, while running, it trips the breaker. Your pressure should be much lower, maybe 5-10 psi, without the cartridge in place. Hayward Aquarite T-CELL-5 | 20,000G Replacement Cell - Salt Pool Store Could the filter be plumbed backwards possibly? 1. 4. remove rear motor cover, loosen screw that holds capacitor (9 oclock) and move it out of the way, so you can fit a 7/16 wrench on the rear of the motor shaft, behind the centrifugal switch. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. "logo": {
Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. Hi Bill, when it goes into spa mode, the spa drain valve should open, and close off the pool suction valves, so that all the water is coming into the pump from the spa only. Hi, it does sound like a bad seal yes. Any tips? I have a brand new Hayward super pump for my inground pool that my husband bought last year..this morning i turned it on and when i checked it about an hour later i noticed it was off and water around the switch and the plug and i also noticed there must have been a leak in the hose where the water can be drained from the pool so im guessi g the hose sprung a leak and wet everything..i checked the timer and the breaker and switched them off and on again and still no power..i saw a switch on the back of the pump and flipped it off then on again and still no power..im guessing it couldve got fried but im hoping im wrong..please help. All breakers are good. The ampage to the pump has been the same since we got the pump 7 years ago and never had this issue before. The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. When they fail, they often crack, bulge, leak or smell bad, but not always. Water level is good, pipe connections are sealed and I checked I rings which seem fineI cant seem to figure out what is wrong. We replaced fhe shaft seal but the pump doesnt pull any water in there is no suction. No lights are coming on as if no power. No moisture. As I started to prep for this season, I did notice that the positive and negative electrical terminals on the 3 prong cord were corroded and loose. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. To reset your average salt level, turn the unit to OFF and then back to AUTO. Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. Slide your main switch to the AUTO position. Thanks a lot! If you are running the pump at full steam, and then shut it off, while looking very closely at these areas, you may see a quick spurt of water, which is where the air leak is originating from. 1.5 hayward pool pump motor clicks on and off rapidy. more, View Hi Virgil, the time clock may not be set, or if you have a controller, the on/off program may not be setup, so it runs until it is set to turn off but is not set to turn back on again? Ours is doing the same thing. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. The article says: Check for possible disruption inside of the flow T. Installation requires 12 inches of straight pipe before the flow switch. The issue is not a pump problem, not a filter problem, but a multiport valve problem. You can consult the flow charts for each model, to compare flow rates among two pumps, with a given (or assumed) level of resistance (feet of head). Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. Minglin. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. We have parts for the Super pump. Inspect the pipe/union connections on the suction side for loose connections or damaged pipes. "publisher": {
Home / Pool Equipment / Pool Heaters & Heat Pumps / Hayward Pool Heater Troubleshooting Hayward Pool Heater Troubleshooting September 24, 2019 March 3, 2023 Mark Garcia Check the wiring in the back of the motor, is the cord firmly attached? Pull the motor out of the pump and turn it on briefly, to see if the noise remains. Turned it off tho clear the skimmer basket.. water level is correct. Power Pole Distribution Block, I bought a new pump thinking was something wrong with pump on off switch. I checked the 20A fuse and it is good. This error can result commonly in springtime, after the pump has sat all winter rust can develop between the stator and rotor. When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. 3. It trips 20amp breaker after running 5 or 10 second. I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. Hi Rose, Its common that winterized pumps may freeze up, caused by a rust layer inside the motor. What do I need to do to fix this? Any idea what the next most likely culprit could be? Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Also be sure the vent holes for the motor are not blocked. I think I have a different problem with the pump now. The pipe connection became disconnected and flooded the pool house overnight after initial opening and start up pull the water through. Profile, Create a Pool Professional voltage reachs the stationary switch. Last year it worked great. We cant figure put how to get the pump going they have a circuit box outside its hooked to but it seems its not working. It is usually set to run at high rpm early morning and that is before sun hits it. Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. Thats good such frozen motors are common in the spring. We opened the pool a few weeks back with no pump motor problems. Do you have any idea what I need to do to remedy the problem. Turned on the motor and smoke and a oil type substance came out of the capacitor. Water Features, View All More commonly, you may experience sparks, or a small popping sound as you drain the capacitor, if there is a lot of power stored. You might also check the the motor is not bound up, reaching in behind the basket to be sure you can spin the impeller with your fingertips. You will need a new plug and a new outlet and maybe a new pump too (? You could use a small plug-in pump timer that would allow you to not unplug, just flip the switch to off. Samsung Da29-00020b 3 Pack, The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. how to watch past broadcasts on twitch. if it does not come back on, check switches, turn breaker all the way off and back on again. What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). How can I secure the top to the filter so the water will not pour out of it while the pump is on filter mode?

Fox Nation Customer Service Phone, Most Famous Far Side Cartoons, Why Do Sovereign Citizens Say They Are Traveling, Message From A Loved One In Heaven App, When To Separate Pregnant Guppy, Articles H

Follow me!

hayward blue essence troubleshooting